Sysmex XN-330 automated haematology analyzer
An entry-level Sysmex analyzer that brings XN-Series technology and a 6-part white cell differential to smaller labs. Milap International supplies, installs and services the XN-330 as an authorised Sysmex partner.
- 6-part differential including immature granulocytes (IG)
- Up to 60 samples/hour in whole blood mode
- Open-tube sampling with colour touchscreen
- 25 µL whole blood sample volume
What is the Sysmex XN-330?
The Sysmex XN-330 is a compact benchtop haematology analyzer from the XN-L series. It gives a complete blood count (CBC) with a 6-part white cell differential, including an immature granulocyte (IG) count, using the same fluorescent flow cytometry as larger Sysmex XN analyzers. It uses manual open-tube sampling and suits small labs, clinics and nursing homes that want a full differential without a large analyzer.
Key features
6-part differential with IG
Neutrophils, lymphocytes, monocytes, eosinophils and basophils plus an immature granulocyte count, with no extra reagents.
XN-Series technology
Fluorescent flow cytometry for white cells and impedance with hydrodynamic focusing for red cells and platelets.
Cyanide-free haemoglobin
Haemoglobin is measured with a cyanide-free SLS method.
Small footprint
A compact benchtop design that fits small lab benches.
Touchscreen software
An integrated colour touchscreen with the same intuitive XN software used across the range.
Micro-sample friendly
Works with standard tubes and micro-collection tubes, with a pre-dilute mode for small samples.
How a CBC runs on the XN-330
- Collect the blood sample in an EDTA tube; standard and micro-collection tubes are supported.
- Open the tube and present it to the sample probe, which aspirates 25 µL of whole blood.
- The analyzer counts red cells and platelets by impedance, measures haemoglobin with a cyanide-free method and separates white cells by fluorescent flow cytometry.
- Results, flags and scattergrams appear on the touchscreen within about a minute and can be sent to your LIS.
Specifications
| Specification | Sysmex XN-330 |
|---|---|
| Analyzer type | Automated haematology analyzer, 6-part differential |
| Technology | WBC/DIFF: fluorescent flow cytometry; RBC/PLT: DC impedance with hydrodynamic focusing; HGB: cyanide-free SLS method |
| Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, NEUT, LYMPH, MONO, EO, BASO, IG (# and %) |
| Throughput | Up to 60 samples per hour (whole blood mode) |
| Sample volume | 25 µL whole blood; 70 µL pre-dilute mode |
| Sampling | Manual, open tube |
| Linearity | WBC 0–440 × 10³/µL; RBC 0–8.6 × 10⁶/µL; PLT 0–5,000 × 10³/µL |
| Data storage | 10,000 sample results |
| Quality control | XN-L CHECK tri-level controls; 20 QC files |
| Maintenance | Daily shutdown and weekly cleaning cycle |
| Dimensions and weight | About 45 × 46.5 × 51.5 cm (W × H × D); about 35 kg |
Download the official Sysmex XN-330, XN-430 and XN-530 brochure (PDF, 2.5 MB)
Source: Sysmex XN-L series (XN-330/430/530) brochure. Specifications and availability can vary by market; ask us for the current Indian configuration.
Who is the XN-330 for?
The XN-330 suits small hospital labs, clinics, nursing homes and collection centres that run a modest number of CBCs each day. Labs moving up from a 3-part analyzer get a fuller differential and an IG count, using the same technology, reagents and controls as larger Sysmex XN analyzers.
Compare the Sysmex XN range
| Model | Sampling | Best for |
|---|---|---|
| XN-330 | Manual, open tube | Small labs and clinics |
| XN-350 | Manual, open tube; RET and body fluid options | Small and mid-sized labs |
| XN-550 | Automated sample loader, rerun and reflex | Busy hospital and diagnostic labs |
| XN-1000 | High-throughput automated sampler | Large hospital and reference labs |
Installation, training and service
Installation and commissioning
Site checks, set-up, calibration and first-run verification by Milap engineers.
Application training
Hands-on training for technicians on daily runs, QC and maintenance.
Reagents and controls
Genuine Sysmex reagents and controls supplied from Bengaluru.
AMC, CMC and breakdown support
Preventive maintenance plans, with breakdown calls answered during evenings and weekends.
Related products
Compact analyzer with RET and body fluid options.
Compact analyzer with an automated sample loader.
High-throughput analyzer for large labs.
Automated coagulation analyzer.
Related guide
3-part vs 5-part hematology analyzer
Which your laboratory needs.
Frequently asked questions
It runs a complete blood count with a 6-part white cell differential, including immature granulocytes (IG).
Up to 60 samples per hour in whole blood mode.
Both use manual open-tube sampling. The XN-350 adds a low WBC mode, optional reticulocyte and body fluid analysis and larger data storage (100,000 results against 10,000).
It aspirates 25 µL in whole blood mode and 70 µL in pre-dilute mode.
Yes. Haemoglobin is measured with a cyanide-free SLS method.
Yes. Milap engineers install and commission the analyzer, train your staff, supply genuine reagents and controls, and offer preventive maintenance, AMC or CMC with breakdown support from Bengaluru.
Milap International, based in Bengaluru, is an authorised channel partner and supplies the Sysmex XN-330 automated haematology analyzer to hospitals, laboratories and clinics across Karnataka, with installation, training and service from the same team.
The price depends on the model, configuration, accessories and service terms you choose. Request a quote with your requirement and a product specialist will reply with a written price within 24 hours.
Get a quote for the Sysmex XN-330
Tell us your daily CBC volume and we will send pricing, reagent costs and a service plan.
