Xenios console ECMO system by Fresenius Medical Care

Xenios ECMO system

The Xenios ECMO system from Fresenius is an ECMO machine for VV and VA ECMO, paediatric ECMO and CO2 removal, for patients from neonates to adults. Milap International supplies, installs and services Xenios ECMO systems as an authorised Fresenius partner.

  • VV and VA ECMO plus ECCO2R
  • Neonate to adult patient range
  • Up to 29 days Novalung kit application
  • Dual batteries hot-swappable backup

What is the Xenios ECMO system?

Xenios ECMO is the extracorporeal life support (ECLS) platform from Xenios AG, part of Fresenius Medical Care. The current Xenios 2.0 console, successor to the Xenios console, runs veno-venous and veno-arterial ECMO, paediatric ECMO, synchronised cardiac support and CO2 removal with Novalung patient kits, for intensive care teams treating severe heart and lung failure.

Key features

Full ECLS range

VV and VA ECMO, paediatric ECMO, synchronised cardiac support and ECCO2R.

Integrated pressure sensors

Built into the disposables to avoid air aspiration at pressure ports.

Dual backup batteries

Two battery packs plus a direct pump-to-battery connection.

Alarm guidance

Alarms with recommended actions and trend views of key parameters.

Guided set-up

Step-by-step screens for priming and preparation.

Data connectivity

Treatment data transfer to hospital PDMS and EMR systems.

How ECMO runs on the Xenios platform

  1. Choose a Novalung kit sized for the patient and prime it using the guided screens.
  2. Cannulate the patient (veno-venous or veno-arterial) and connect the circuit.
  3. Set pump speed, blood flow and sweep gas while integrated sensors and alarms watch the circuit.
  4. Wean the patient from support and decannulate.
ICU doctor and nurse caring for a patient with low oxygen saturation

Specifications

SpecificationXenios ECMO system
TherapiesVV and VA ECMO, paediatric ECMO, synchronised cardiac support, ECCO2R
Patient rangeNeonates to adults
Display10.4-inch TFT touchscreen
Pump drive0–10,000 rpm
Pressure sensors4 integrated sensors (−680 to +600 mmHg)
Battery runtime120–420 minutes
Operator unit weight (Xenios 2.0)8.5 kg
Kit coatingx.ellence heparin/albumin coating
Kit application timeUp to 29 days (Novalung kits, MDR)

Download the official Fresenius Xenios console (ECMO) brochure (PDF, 2 MB)

Source: Xenios AG product pages for Xenios 2.0 and the Xenios console. Ask us which console version is available in India.

Consumables for the Xenios ECMO system

Milap International supplies the Fresenius consumables for the Xenios ECMO system, so the console and its disposables come from one place. The platform runs on Novalung patient kits, which are sized for the patient. The wider Fresenius range we supply is listed below it. Ask us for current kit models, availability and pack sizes.

No.ConsumableType
1Novalung patient kitsPatient kit (ECMO and ECCO2R)
2Adult FX8 Single Use DialyserDialyser
3Adult Blood TubingBlood tubing set
4Paediatric Dialyser F4Dialyser
5Paediatric Blood TubingBlood tubing set
6Adult IJV Catheter 11.5FCatheter
7Adult FC Catheter 11.5FCatheter
8Paediatric FC Catheter 8.5FCatheter
9CitrosterileMachine disinfection
10Bibag 900 GmsDialysate bicarbonate
11Acid Can 2KDialysate acid concentrate
12Acid Can 4KDialysate acid concentrate
13DiasafeDialysate filter
14Plasmapheresis Dialyser (P1)Plasmapheresis
15Plasmapheresis Dialyser (P2) AdultPlasmapheresis

Who is Xenios ECMO for?

Xenios ECMO suits cardiac, respiratory and paediatric intensive care units and ECMO centres, including teams that transfer ECMO patients between hospitals.

Critical care team monitoring a patient

Compare Fresenius systems

SystemTherapyTypical setting
4008S NGHaemodialysisDialysis units and hospital nephrology
5008S CorDiaxHaemodialysis and online HDFDialysis centres moving to HDF
multiFiltratePROCRRT, citrate anticoagulation, plasma exchangeIntensive care units
Xenios ECMOVV and VA ECMO, ECCO2RCardiac and respiratory ICUs

Installation, training and service

Installation and commissioning

Site, water and electrical checks, set-up and first-run support by Milap engineers.

Clinical application training

Hands-on training for nurses, technicians and doctors.

Consumables and spares

Genuine Fresenius consumables and spare parts supplied from Bengaluru.

AMC, CMC and breakdown support

Preventive maintenance plans, with breakdown calls answered during evenings and weekends.

Frequently asked questions

Extracorporeal membrane oxygenation pumps blood outside the body through an artificial lung to add oxygen and remove carbon dioxide, supporting patients with severe lung or heart failure.

Veno-venous (VV) ECMO supports the lungs only. Veno-arterial (VA) ECMO supports both the heart and the lungs.

Yes. The platform covers patients from neonates to adults, with dedicated paediatric kits.

Novalung kits are certified for up to 29 days of use under MDR.

The console has dual hot-swappable backup batteries with 120–420 minutes of runtime.

Yes. Milap engineers install and commission the system, train your team, supply genuine consumables and spares, and offer preventive maintenance, AMC or CMC with breakdown support from Bengaluru.

From Milap International in Bengaluru, an authorised Fresenius channel partner. We supply the Xenios ECMO system to hospitals across Karnataka, with installation, ICU team training and service from the same team.

ECMO machine price depends on the console configuration, the kits and consumables used for each patient, and the service plan. Request a quote with your requirement and a product specialist will reply with a written price within 24 hours.

Get a quote for the Xenios ECMO system

Tell us about your ICU or ECMO programme, and we will send pricing and a service plan.