Xenios ECMO system
The Xenios ECMO system from Fresenius is an ECMO machine for VV and VA ECMO, paediatric ECMO and CO2 removal, for patients from neonates to adults. Milap International supplies, installs and services Xenios ECMO systems as an authorised Fresenius partner.
- VV and VA ECMO plus ECCO2R
- Neonate to adult patient range
- Up to 29 days Novalung kit application
- Dual batteries hot-swappable backup
What is the Xenios ECMO system?
Xenios ECMO is the extracorporeal life support (ECLS) platform from Xenios AG, part of Fresenius Medical Care. The current Xenios 2.0 console, successor to the Xenios console, runs veno-venous and veno-arterial ECMO, paediatric ECMO, synchronised cardiac support and CO2 removal with Novalung patient kits, for intensive care teams treating severe heart and lung failure.
Key features
Full ECLS range
VV and VA ECMO, paediatric ECMO, synchronised cardiac support and ECCO2R.
Integrated pressure sensors
Built into the disposables to avoid air aspiration at pressure ports.
Dual backup batteries
Two battery packs plus a direct pump-to-battery connection.
Alarm guidance
Alarms with recommended actions and trend views of key parameters.
Guided set-up
Step-by-step screens for priming and preparation.
Data connectivity
Treatment data transfer to hospital PDMS and EMR systems.
How ECMO runs on the Xenios platform
- Choose a Novalung kit sized for the patient and prime it using the guided screens.
- Cannulate the patient (veno-venous or veno-arterial) and connect the circuit.
- Set pump speed, blood flow and sweep gas while integrated sensors and alarms watch the circuit.
- Wean the patient from support and decannulate.
Specifications
| Specification | Xenios ECMO system |
|---|---|
| Therapies | VV and VA ECMO, paediatric ECMO, synchronised cardiac support, ECCO2R |
| Patient range | Neonates to adults |
| Display | 10.4-inch TFT touchscreen |
| Pump drive | 0–10,000 rpm |
| Pressure sensors | 4 integrated sensors (−680 to +600 mmHg) |
| Battery runtime | 120–420 minutes |
| Operator unit weight (Xenios 2.0) | 8.5 kg |
| Kit coating | x.ellence heparin/albumin coating |
| Kit application time | Up to 29 days (Novalung kits, MDR) |
Download the official Fresenius Xenios console (ECMO) brochure (PDF, 2 MB)
Source: Xenios AG product pages for Xenios 2.0 and the Xenios console. Ask us which console version is available in India.
Consumables for the Xenios ECMO system
Milap International supplies the Fresenius consumables for the Xenios ECMO system, so the console and its disposables come from one place. The platform runs on Novalung patient kits, which are sized for the patient. The wider Fresenius range we supply is listed below it. Ask us for current kit models, availability and pack sizes.
| No. | Consumable | Type |
|---|---|---|
| 1 | Novalung patient kits | Patient kit (ECMO and ECCO2R) |
| 2 | Adult FX8 Single Use Dialyser | Dialyser |
| 3 | Adult Blood Tubing | Blood tubing set |
| 4 | Paediatric Dialyser F4 | Dialyser |
| 5 | Paediatric Blood Tubing | Blood tubing set |
| 6 | Adult IJV Catheter 11.5F | Catheter |
| 7 | Adult FC Catheter 11.5F | Catheter |
| 8 | Paediatric FC Catheter 8.5F | Catheter |
| 9 | Citrosterile | Machine disinfection |
| 10 | Bibag 900 Gms | Dialysate bicarbonate |
| 11 | Acid Can 2K | Dialysate acid concentrate |
| 12 | Acid Can 4K | Dialysate acid concentrate |
| 13 | Diasafe | Dialysate filter |
| 14 | Plasmapheresis Dialyser (P1) | Plasmapheresis |
| 15 | Plasmapheresis Dialyser (P2) Adult | Plasmapheresis |
Who is Xenios ECMO for?
Xenios ECMO suits cardiac, respiratory and paediatric intensive care units and ECMO centres, including teams that transfer ECMO patients between hospitals.
Compare Fresenius systems
| System | Therapy | Typical setting |
|---|---|---|
| 4008S NG | Haemodialysis | Dialysis units and hospital nephrology |
| 5008S CorDiax | Haemodialysis and online HDF | Dialysis centres moving to HDF |
| multiFiltratePRO | CRRT, citrate anticoagulation, plasma exchange | Intensive care units |
| Xenios ECMO | VV and VA ECMO, ECCO2R | Cardiac and respiratory ICUs |
Installation, training and service
Installation and commissioning
Site, water and electrical checks, set-up and first-run support by Milap engineers.
Clinical application training
Hands-on training for nurses, technicians and doctors.
Consumables and spares
Genuine Fresenius consumables and spare parts supplied from Bengaluru.
AMC, CMC and breakdown support
Preventive maintenance plans, with breakdown calls answered during evenings and weekends.
Related products
CRRT system for intensive care.
Haemodialysis and online HDF system.
Haemodialysis machine for dialysis units.
Frequently asked questions
Extracorporeal membrane oxygenation pumps blood outside the body through an artificial lung to add oxygen and remove carbon dioxide, supporting patients with severe lung or heart failure.
Veno-venous (VV) ECMO supports the lungs only. Veno-arterial (VA) ECMO supports both the heart and the lungs.
Yes. The platform covers patients from neonates to adults, with dedicated paediatric kits.
Novalung kits are certified for up to 29 days of use under MDR.
The console has dual hot-swappable backup batteries with 120–420 minutes of runtime.
Yes. Milap engineers install and commission the system, train your team, supply genuine consumables and spares, and offer preventive maintenance, AMC or CMC with breakdown support from Bengaluru.
From Milap International in Bengaluru, an authorised Fresenius channel partner. We supply the Xenios ECMO system to hospitals across Karnataka, with installation, ICU team training and service from the same team.
ECMO machine price depends on the console configuration, the kits and consumables used for each patient, and the service plan. Request a quote with your requirement and a product specialist will reply with a written price within 24 hours.
Get a quote for the Xenios ECMO system
Tell us about your ICU or ECMO programme, and we will send pricing and a service plan.