Sysmex CN-6000 / CN-3000 automated coagulation analyzer
Next-generation Sysmex coagulation analyzers that bring routine and specialty haemostasis testing, including platelet aggregation, into a small footprint. The CN-6000 runs up to 450 PT tests per hour and the CN-3000 up to 225. Milap International supplies, installs and services both across Karnataka.
- Up to 450 PT tests/hour CN-6000 (CN-3000: 225)
- Up to 60 parameters routine and specialty
- Platelet aggregation with automatic agonist dilution
- Up to 3 analyzers on the Sysmex haemostasis transport system
What are the Sysmex CN-6000 and CN-3000?
The Sysmex CN-6000 and CN-3000 are fully automated coagulation (haemostasis) analyzers. Both use multi-wavelength detection at 340 to 800 nm with a long-life LED light source and a pre-analytical HIL check, and both run routine and specialty assays, including platelet aggregation, on one system. The CN-6000 is built for higher volumes; the CN-3000 for low to mid volumes in the same footprint.
Key features
High throughput
Up to 450 PT tests per hour on a stand-alone CN-6000, and up to 225 on the CN-3000.
Routine and specialty on one system
Clotting, chromogenic and immunoassay tests plus platelet aggregation.
Accurate on difficult samples
Multi-wavelength detection with HIL (haemolysis, icterus, lipaemia) check and automatic sensitivity switching for lipaemic samples.
Reagent planning tool
Estimates the reagent vials needed for the planned daily routine, so runs are not interrupted.
Automatic agonist dilution
Platelet aggregation agonists are diluted on board; direct connection to a water purification system is possible.
Self-diagnostics
Continuous instrument checks and an on-board interactive guide for troubleshooting reduce unexpected downtime.
Specifications
| Specification | Sysmex CN-6000 / CN-3000 |
|---|---|
| Detection principle | Multi-wavelength detector for transmitted light at 340, 405, 575, 660 and 800 nm (both models) |
| Channels, CN-6000 | 26 for clotting, chromogenic and immunoassays (8 also used for platelet aggregation) |
| Channels, CN-3000 | 13 for clotting, chromogenic and immunoassays (4 also used for platelet aggregation) |
| Parameters | Up to 60 analysed simultaneously (both models) |
| Throughput, CN-6000 | PT: 450 tests/hour; PT/APTT: 401 tests/hour |
| Throughput, CN-3000 | PT: 225 tests/hour; PT/APTT: 215 tests/hour |
| Sampling | 5 racks of 6 tubes (standard sampler) or 20 racks (optional sampler); cap-piercing; 1 dedicated STAT position; direct sampling from an automation track |
| Reagent positions | 38 tilted, cooled (10 °C), 7 with mixing; 6 at room temperature; positive reagent identification |
| Automation | Up to three CN analyzers on the Sysmex haemostasis island transport system (up to 1,000 tubes/hour) |
Throughput figures are for a stand-alone analyzer. Reagent and assay availability varies by country; ask us for the current menu in India.
Who are the CN-6000 and CN-3000 for?
Hospital and reference laboratories that want high coagulation throughput and specialty testing such as platelet aggregation in a small footprint. The CN-3000 suits low to mid volumes; the CN-6000 suits mid to high volumes and labs planning haemostasis automation.
CN-6000 or CN-3000?
| CN-6000 | CN-3000 | |
|---|---|---|
| PT throughput | Up to 450 tests/hour | Up to 225 tests/hour |
| PT/APTT throughput | Up to 401 tests/hour | Up to 215 tests/hour |
| Channels | 26 (8 for aggregation) | 13 (4 for aggregation) |
| Footprint | Same as CN-3000 | Same as CN-6000 |
Installation, training and service
Installation and commissioning
Site check, set-up, calibration and first-run verification by Milap engineers, including LIS connection.
Application training
Hands-on training on PT/INR, APTT, fibrinogen, QC and daily maintenance.
Reagents and controls
Genuine reagents, calibrators and controls for your test menu, supplied from Bengaluru.
AMC, CMC and breakdown support
Preventive maintenance plans, with breakdown calls answered during evenings and weekends.
Related products
High-volume coagulation with platelet aggregation.
Compact benchtop coagulation analyzer.
How to choose a coagulation analyzer
Test menu, throughput and sample errors.
Frequently asked questions
Throughput and channels. The CN-6000 runs up to 450 PT tests per hour with 26 channels; the CN-3000 runs up to 225 PT tests per hour with 13 channels. Both share the same footprint and technology.
Routine and specialty haemostasis tests, including PT, APTT, fibrinogen, D-dimer, factor assays, lupus anticoagulant, antithrombin, protein C and S, von Willebrand factor and platelet aggregation.
Yes. Both run platelet aggregation, and the agonists are diluted automatically on board.
They check haemolysis, icterus and lipaemia before testing and switch detection sensitivity automatically for lipaemic samples.
Yes. Up to three CN analyzers can be linked on the Sysmex haemostasis island transport system, which handles up to 1,000 tubes per hour, or connected to a laboratory automation track.
Yes. Milap engineers plan the site, install and commission the analyzer, connect it to your LIS, train your staff, and offer AMC or CMC with breakdown support from Bengaluru.
From Milap International in Bengaluru. We supply, install and service both models for laboratories across Karnataka.
It depends on the model (CN-6000 or CN-3000), your test menu, daily volume, automation needs and the reagent and service plan. Request a quote and we will send a written price.
Get a quote for the Sysmex CN-6000 / CN-3000
Tell us your daily coagulation volume and specialty tests, and we will suggest the CN-6000 or CN-3000 and the right set-up.