Sysmex UF-5000 / UF-4000 fully automated urine particle analyzer
Fully automated urine particle analyzers that use fluorescence flow cytometry with a blue laser to analyse native urine in under a minute per sample, with a body fluid mode built in. The UF-5000 runs up to 105 urine samples per hour and the UF-4000 up to 80. Milap International supplies, installs and services both across Karnataka.
- Up to 105 samples/hour UF-5000 urine mode (UF-4000: 80)
- 28 urine parameters and 9 in body fluid mode
- UTI and bacteria flags including Gram positive / negative information
- UN-Series core links to UC-3500 and UD-10
What are the Sysmex UF-5000 and UF-4000?
The Sysmex UF-5000 and UF-4000 are fully automated urine particle analyzers based on fluorescence flow cytometry. They count and classify thousands of particles in native urine, without centrifugation, and report red and white cells, epithelial cells, casts, bacteria and crystals. Both have a body fluid mode, and both can run alone or as the core of the modular Sysmex UN-Series.
Key features
Blue laser FFC
Fluorescence flow cytometry with a 488 nm blue laser and two analysis channels (surface and core) for better particle differentiation.
UTI information
Urinary tract infection and bacteria information flags, including Gram positive or Gram negative information, to support early treatment decisions.
Haematuria assessment
Depolarised side scatter helps separate red cells from crystals, with a red cell morphology information flag.
Body fluid mode
Always on board, with 9 parameters including WBC differential and bacteria count.
Native urine
No centrifugation or pre-treatment, which removes common sources of error and standardises results.
Modular
Works alone or with the UC-3500 and UD-10 in a load-and-leave UN-Series line, managed through U-WAM software.
Specifications
| Specification | Sysmex UF-5000 / UF-4000 |
|---|---|
| Technology | Fluorescence flow cytometry with blue semiconductor laser (488 nm) and hydrodynamic focusing; surface and core channels; depolarised side scatter |
| Throughput, UF-5000 | Urine up to 105 samples/hour; body fluid up to 20 samples/hour |
| Throughput, UF-4000 | Urine up to 80 samples/hour; body fluid up to 15 samples/hour |
| Aspiration volume | 0.45 mL |
| Minimum sample volume | 2 mL in sampler mode (urine); 0.6 mL in STAT mode (urine and body fluid) |
| Parameters | Urine: 28; body fluid: 9 |
| Body fluid parameters | RBC, WBC, MN#, MN%, PMN#, PMN%, EC, TNC, BACT |
| Flags | Urinary tract infection information; bacteria information; red blood cell morphology information |
| Reagents | UF-Cellsheath, UF-Cellpack SF, UF-Cellpack CR, UF-Fluorocell SF, UF-Fluorocell CR, UF-Control (2 levels) |
Who are the UF-5000 and UF-4000 for?
Hospital and reference laboratories with a high daily urine workload, labs that also want body fluid cell counts on the same analyzer, and labs planning a fully automated Sysmex UN-Series line. The UF-4000 suits slightly lower volumes.
UF-5000 or UF-4000?
| UF-5000 | UF-4000 | |
|---|---|---|
| Urine throughput | Up to 105 samples/hour | Up to 80 samples/hour |
| Body fluid throughput | Up to 20 samples/hour | Up to 15 samples/hour |
| Technology | Blue laser fluorescence flow cytometry | Blue laser fluorescence flow cytometry |
| UN-Series connection | Yes | Yes |
Installation, training and service
Installation and commissioning
Site check, set-up, calibration and first-run verification by Milap engineers, including LIS connection.
Application training
Hands-on training for your technicians on daily start-up, QC, sample runs and maintenance.
Reagents, strips and controls
Genuine Sysmex reagents, test strips and controls supplied from Bengaluru.
AMC, CMC and breakdown support
Preventive maintenance plans, with breakdown calls answered during evenings and weekends.
Related products
Fully automated urine chemistry.
Digital images of flagged samples.
Compact particle analyzer for smaller labs.
Frequently asked questions
The Sysmex UF-5000 and UF-4000 differ in throughput: the UF-5000 runs up to 105 urine samples per hour and the UF-4000 up to 80, with body fluid throughput of 20 and 15. The technology is the same.
No. The Sysmex UF-5000 analyses native urine without centrifugation or pre-treatment, using fluorescence flow cytometry with a 488 nm blue laser.
Yes. The Sysmex UF-5000 body fluid mode is always on board and reports 9 parameters, including a WBC differential and bacteria count.
Yes. The Sysmex UF-5000 gives urinary tract infection and bacteria information flags, including Gram positive or Gram negative information, to support early treatment decisions.
The Sysmex UF-5000 needs a minimum of 2 mL of urine in sampler mode or 0.6 mL in STAT mode, and aspirates 0.45 mL.
Yes. The UF-5000 is the core of the Sysmex UN-Series and connects to the UC-3500 urine chemistry analyzer and the UD-10 digital imaging device, managed through U-WAM.
Milap International supplies, installs and services the Sysmex UF-5000 and UF-4000 urine particle analyzers for laboratories across Karnataka.
The Sysmex UF-5000 price depends on the model (UF-5000 or UF-4000), whether it is part of a UN-Series line, your daily sample volume and the reagent and service plan. Request a quote and Milap sends a written price.
Get a quote for the Sysmex UF-5000 / UF-4000
Tell us your daily urine and body fluid sample counts, and we will suggest the UF-5000 or UF-4000 and the right UN-Series set-up.