CLINITEK Status® Connect System

Need more control over your point-of-care urinalysis testing process?

The CLINITEK Status® Connect System streamlines point-of-care urinalysis with wireless and wired connectivity, ensuring efficient testing oversight and enhanced risk management. It integrates seamlessly with LIS, EMR, and data management solutions, improving workflow efficiency and compliance across testing sites. With advanced barcode scanning, operators can quickly enter lot and expiration data, while Auto-Checks technology ensures accurate results interpretation and quality control, preventing unauthorized use and driving clinical reliability.

Features & Benefits

Centralize control over your point-of-care urinalysis testing program with the CLINITEK Status Connect

Supports Flexible & Efficient Connectivity

The CLINITEK Status® Connect System enables seamless integration with hospital LIS, HIS, EMR, and point-of-care middleware solutions, ensuring efficient data management and centralized control. With wireless, Ethernet, and serial transmission capabilities, it supports HL7 and POCT1-A2 protocols, allowing smooth interoperability with leading data management systems like Siemens’ RAPIDComm® Data Management System, Conworx Technology POCcelerator™, MAS RALS®-Plus, and TELCOR Quick-Linc®

Advanced Operational Control and Management

The CLINITEK Status® Connect System enhances security and access control with customized operator access levels, operator ID entry, and lockout features, preventing unauthorized use through customizable settings. This ensures compliance, data integrity, and efficient point-of-care diagnostics, optimizing workflow management in clinical environments

Enhanced Quality Control

The CLINITEK Status® Connect System enhances workflow efficiency with an optional barcode reader, eliminating manual steps and reducing transcription errors. It ensures up-to-date operator certification records, restricts access as needed, and supports customized QC protocols across multiple sites. With QC lockout for non-compliance, on-demand QC documentation, and the ability to store up to 200 QC test records, this system optimizes quality control and data accuracy in point-of-care diagnostics

Improved Data Integrity

The CLINITEK Status®+ Analyzer ensures accurate urinalysis results with Auto-Checks technology, preventing false readings by detecting humidity exposure and sample interferences while providing printed notations for improved interpretation. With Siemens strip auto-identification, it streamlines workflows, saving time and enhancing point-of-care efficiency

Assays

The CLINITEK Status Connect System provides automated reading of the Multistix® family of urinalysis tests:

Technical Specifications

Semi-quantitative Tests Measured Routine urine tests albumin, bilirubin, creatinine, glucose, ketone, leukocytes, nitrite, pH, protein, specific gravity and urobilinogen
Kidney disease test albumin-to-creatinine ratio
Pregnancy test Human Chorionic Gonadotropin (hCG)
General Specifications Depth 10.7 in. or 27.2 cm
Width 6.7 in. or 17.1 cm
Height 7.5 in. or 18.5 cm
Weight 5.0 lbs or 2.3 kg
Electrical rating 100V - 240V AC, 50-60 Hz (with in-line lead)
Battery operation Not available
Ambient temperature range 18 to 30ºC (64 to 86ºF)
Humidity range 18-80% relative humidity, non-condensing
Compliance UL, CE, EMC
Calibration automatic, self-calibrating
Communication Capabilities Communication protocol HL7, POCT1-A2
Data transmission options wireless, Ethernet or serial connection
Interfaces with leading point-of-care
data management solutions*
  • Siemens’ RAPIDComm® Data Management and Connectivity Solution
  • MAS RALS®-Plus
  • Telcor Quick-Linc®
  • POCcelerator™

Memory
Patient test results 700
QC test results 200
Operator IDs 700
Quality Control Management Features QC testing and reporting
QC reminders or mandatory prompt
QC lockout
Barcode Data Entry Patient ID, operator ID and name,
QC control type, lot number, and expiration date
Barcode Symbology Supported Code 93, Code 39 (with and without check digit), Code 128, Coda Bar, Interleaved 2 of 5 (with and without check digit)
Operator Security Features Define up to 700 operators
Operator lock-out to prevent unauthorized use
Customize access level for each operator for the following functions:
  • Performing patient tests
  • Performing QC tests
  • Recalling results
  • Modifying system settings