RAPIDLab® 1200 Systems

Perfect choice for medium to high workload environments

For hospital central labs running a high volume of blood gas tests every day, the RAPIDLab 1200 is the workhorse. It combines testing speed with the kind of reliability that busy labs depend on. Results come back in about 60 seconds, and the system’s Ready Sensor electrode technology has been proven across thousands of installations worldwide.

Our engineers have been maintaining RAPIDLab systems across Karnataka for years. We know every sensor, every fluid path, every calibration cycle on these machines. When you get a RAPIDLab 1200 through Milap International, it comes with complete installation, staff training, scheduled preventive maintenance, and breakdown support.

Here is what makes the RAPIDLab 1200 a solid choice for central labs and high-volume testing sites:

Features & Benefits

The RAPIDLab 1200 is built for hospital environments where the lab runs hundreds of blood gas tests daily. Whether it is a medical college hospital, a large government institution, or a busy private hospital, this system handles the volume without compromising on accuracy:

For neonatal intensive care units, the RAPIDLab 1200 is an especially strong choice. Neonatal patients need tiny sample volumes, fast results, and absolute accuracy because there is no room for repeat draws on premature infants:

RAPIDLab 1200 Systems’ testing performance, accuracy and consistency make it an excellent choice as your NICU monitoring solution:

When it comes to such small and vulnerable patients, fast results, delivered instantly, can make a big difference.

Get a complete picture in just 1 minute

Increase your throughput

Get lab-quality results and help ensure regulatory compliance

Assays

Parameters* Analyte
Blood Gas pH
pCO2
pO2
Electrolytes Na+
K+
Ca++
CI-
Metabolites Glucose
Lactate
CO-oximetry tHb
HHb
O2Hb
sO2
COHb
MetHb
Neonatal Total Bilirubin

Technical Specifications

Sample Size: Syringe (1 mL)/Capillary (Minimum) RAPIDLab 1240RAPIDLab 1245RAPIDLab 1260RAPIDLab 1265
pH Only35 µl35 µl95 µl95 µl
CO-oximetry Only--100 µl--100 µl
Full Menu90 µl140 µl125 µl175 µl
Analysis
Time to Results: 60 seconds
Cartridges
Reagent Cartridge Use Life: 30 days
Wash Cartridge Use Life: Sample dependent
AQC Cartridge Use Life: 28 days
Calibration
1 point Calibration Every 30 minutes
Full Cal Calibration Every 8 hours
Environmental
Temperature: 15°C-32°C
Humidity: 5%-85% non-condensing
System Dimensions
Width: 58.4 cm (23.0 in.)
Height: 57.2 cm (22.5 in.)
Depth: 55.9 cm (22 in.)
Weight: 29.5 kg (65 lb)
Power Requirement
Rating: 150VA
Voltage:100-240V
Frequency: 50/60Hz
External Interfaces
USB Printer Port, RS232 Port, Bar Code Scanner Port, RJ10/100 Base T Ethernet Port
Approvals
EN 60601-1-2:2001, Group 1, Class B, CB Test Certificate, UL Certificate, CSA Certified