RAPIDLab® 1200 Systems
Perfect choice for medium to high workload environments





For hospital central labs running a high volume of blood gas tests every day, the RAPIDLab 1200 is the workhorse. It combines testing speed with the kind of reliability that busy labs depend on. Results come back in about 60 seconds, and the system’s Ready Sensor electrode technology has been proven across thousands of installations worldwide.
Our engineers have been maintaining RAPIDLab systems across Karnataka for years. We know every sensor, every fluid path, every calibration cycle on these machines. When you get a RAPIDLab 1200 through Milap International, it comes with complete installation, staff training, scheduled preventive maintenance, and breakdown support.
Here is what makes the RAPIDLab 1200 a solid choice for central labs and high-volume testing sites:
- Comprehensive test menu addresses a variety of critical care testing needs
- Intuitive operation and minimal maintenance help increase productivity without increasing staff.
- Industry-proven accuracy and reliability through long-life Ready Sensor® electrode technology
- Biosafe automatic sampling system with clot detection and clearance
- Effortless onboard Automatic Quality Control (AQC) for enhanced quality assurance and regulatory compliance
Features & Benefits
The RAPIDLab 1200 is built for hospital environments where the lab runs hundreds of blood gas tests daily. Whether it is a medical college hospital, a large government institution, or a busy private hospital, this system handles the volume without compromising on accuracy:
- Extensive test menu includes full CO-oximetry and neonatal total bilirubin
- Ready Sensor® electrode technology for industry-proven reliability
- Cost-effective, cartridge-based system
- Simplified operation with biosafe sampling
- Automatic quality control and documentation
- Seamless integration with your LIS/HIS
- Dedicated technical support and on-site service
For neonatal intensive care units, the RAPIDLab 1200 is an especially strong choice. Neonatal patients need tiny sample volumes, fast results, and absolute accuracy because there is no room for repeat draws on premature infants:
- Ultra-fast sample processing enables immediate physician intervention
- Clinical accuracy reduces the need to repeat tests
- Microsample capability enables testing of very small sample volumes without compromising accuracy
- Full test menu from a single sample
When it comes to such small and vulnerable patients, fast results, delivered instantly, can make a big difference.
Get a complete picture in just 1 minute
- RAPIDLab 1200 Systems
- Blood Gas (pH, pCO2, pO2)
- Electrolytes (Na+, K+, Ca++, Cl- )
- Metabolites (Glucose, Lactate, Neonatal Total Bilirubin)
- CO-oximetry (tHb, HHb, O2Hb, sO2, COHb, MetHb)
- Testing panels can be customized to meet specific needs
- Capable of running the full test menu on short-sample patient draws (microsamples)
Increase your throughput
- Intuitive touchscreen and automatic single sample port (syringe and capillary) speed up the testing process
- All reagents are contained in sealed cartridges for enhanced operator safety and low maintenance
- Clot detection and clearance with biosafe automatic sampling system
Get lab-quality results and help ensure regulatory compliance
- Onboard automatic quality control cartridge requires no operator intervention during the 28-day use life
- The entire sample pathway is analyzed at an operator-definable frequency
- Long-life Ready Sensor® electrodes ensure industry-proven accuracy and reliability
Assays
| Parameters* | Analyte |
|---|---|
| Blood Gas | pH pCO2 pO2 |
| Electrolytes | Na+ K+ Ca++ CI- |
| Metabolites | Glucose Lactate |
| CO-oximetry | tHb HHb O2Hb sO2 COHb MetHb Neonatal Total Bilirubin |
Technical Specifications
| Sample Size: Syringe (1 mL)/Capillary (Minimum) | RAPIDLab 1240 | RAPIDLab 1245 | RAPIDLab 1260 | RAPIDLab 1265 |
|---|---|---|---|---|
| pH Only | 35 µl | 35 µl | 95 µl | 95 µl |
| CO-oximetry Only | -- | 100 µl | -- | 100 µl |
| Full Menu | 90 µl | 140 µl | 125 µl | 175 µl |
| Analysis | ||||
| Time to Results: | 60 seconds | |||
| Cartridges | ||||
| Reagent Cartridge Use Life: | 30 days | |||
| Wash Cartridge Use Life: | Sample dependent | |||
| AQC Cartridge Use Life: | 28 days | |||
| Calibration | ||||
| 1 point Calibration | Every 30 minutes | |||
| Full Cal Calibration | Every 8 hours | |||
| Environmental | ||||
| Temperature: | 15°C-32°C | |||
| Humidity: | 5%-85% non-condensing | |||
| System Dimensions | ||||
| Width: | 58.4 cm (23.0 in.) | |||
| Height: | 57.2 cm (22.5 in.) | |||
| Depth: | 55.9 cm (22 in.) | |||
| Weight: | 29.5 kg (65 lb) | |||
| Power Requirement | ||||
| Rating: | 150VA | |||
| Voltage: | 100-240V | |||
| Frequency: | 50/60Hz | |||
| External Interfaces | ||||
| USB Printer Port, RS232 Port, Bar Code Scanner Port, RJ10/100 Base T Ethernet Port | ||||
| Approvals | ||||
| EN 60601-1-2:2001, Group 1, Class B, CB Test Certificate, UL Certificate, CSA Certified | ||||